ComAp explicitly includes "Wrn Default Password" as an alarm related to user access management. This warning is triggered specifically to alert you that the factory default password is still active, highlighting its importance.
If the InteliLite AMF 25 utilizes an IB-Lite module for internet access, ensure it sits behind a secure firewall or VPN. Avoid assigning public static IP addresses directly to the controller.
If you want, I can:
Press the key (represented by a checkmark or central button) to open the main menu. intelilite+amf+25+default+password
Provide an emergency email address during this process. This allows you to receive a password reset string if you ever forget your new credentials. What to Do if You Forget Your Password
:
Once you have entered the default credentials, it is highly recommended to change them immediately to remove the "default credentials warning" alarm. ComAp explicitly includes "Wrn Default Password" as an
If the password was changed and forgotten, a can restore 0000 as the password. However, this will erase all custom settings .
| Parameter | Value | | :--- | :--- | | | 8 - 36 VDC | | Maximum Power Consumption | 3.5 W | | Operating Temperature Range | -20°C to +70°C | | Nominal Input Current | 5 A (from CT) | | Display | Graphic B/W, 132x64 pixels |
According to manufacturer, some versions use "administrator" as the user and the controller's serial number (found on the label) as the password YouTube: First steps with a ComAp controller . 4. How to Change the Default Password (Highly Recommended) Avoid assigning public static IP addresses directly to
On an InteliLite controller, the password is not needed to view the generator's operating parameters, which are visible on the main screen. Instead, it is required to access and modify "setpoints". These are the controller's configuration parameters, such as nominal voltage and frequency, protection thresholds, and various timers. On the display screen, any protected setpoint is typically marked with a padlock icon, indicating that a password is required to change it. To adjust these locked parameters, you navigate to the relevant menu, select it, and the controller will prompt you for the password.
Connect your PC to the controller using a standard USB interface or internet module.
| Impact Area | Description | |-----------------------|-------------| | Operational Safety | Unauthorized start/stop can endanger maintenance personnel (e.g., unexpected generator energization). | | Power Availability | Malicious parameter changes can prevent automatic transfer or cause nuisance trips. | | Data Integrity | Logs and event history can be cleared or falsified. | | Compliance Violation | Many standards (NERC CIP, IEC 62443, local grid codes) require changing default credentials. |
+-------------------------------------------------------+ | User Level (View-only, basic operations) | +-------------------------------------------------------+ | v +-------------------------------------------------------+ | Operator Level (Standard maintenance, setpoints) | +-------------------------------------------------------+ | v +-------------------------------------------------------+ | Master / Administrator Level (Full system oversight) | +-------------------------------------------------------+ 1. User Level No password required.
If you have forgotten or misplaced the password, do not worry. The Intelilite AMF 25 provides a simple method to reset the password. Follow these steps: