Tridium Niagara 4 User Guide [work] Today
A software platform designed for enterprise-level management, analytics, and archiving. 2. Navigating the Niagara Workbench Interface
Displays graphics (PX views), property sheets, or wire sheets. 3. Slot Sheet vs. Property Sheet
To execute an override, right-click the point, select , Override , or Emergency Override , input your value, and click submit. Always remember to return the point to Auto once your maintenance or troubleshooting session concludes. 6. Managing Schedules
BACnet (Building Automation and Control Networks) is a widely used protocol in building automation systems. Niagara 4 provides robust support for BACnet devices. Here's a step-by-step guide on creating and configuring BACnet devices in Niagara 4:
Operators must right-click an active alarm to Acknowledge it, signaling to the system that the issue is being addressed. Trend Histories tridium niagara 4 user guide
Drag discovered points into the station database.
Drag the network component (e.g., BacnetNetwork ) into your Drivers folder. Device Discovery
A built-in Niagara algorithm that calculates exactly when to start HVAC equipment based on outdoor air temperature, ensuring the building reaches the desired setpoint precisely when occupancy begins. Analyzing Histories and Trends
The Tridium Niagara 4 (N4) Framework has fundamentally changed how building automation systems (BAS) connect, control, and optimize facility operations. By shifting from the legacy Niagara AX framework to a modern, HTML5-centric architecture, Niagara 4 delivers superior speed, enhanced security, and true device agnostic visualization. Always remember to return the point to Auto
Open the Alarm Console to see a live feed of active and unacknowledged faults.
Use the Wire Sheet to link the output of the schedule to the In 16 slot of your target device point. Setting Up Histories (Trending)
Typically reserved for manual overrides, emergency shutdowns, and life safety.
The software engine running the database, logic, and components. A station can run locally on an embedded controller or globally on a server. Station Configuration and Management Choose
Whether you are a building manager, a system integrator, or a curious technician, getting comfortable with is a game-changer for smart building automation.
Niagara 4 acts as a universal translator. To discover and communicate with field hardware, you must install and configure the appropriate driver network.
To connect to a JACE or Supervisor, open Workbench and select . You must authenticate using secure credentials via TLS (Transport Layer Security), which is enabled by default in Niagara 4. 3. Station Configuration and Management
Choose , Date Range , or Week-and-Day (e.g., the fourth Thursday in November).