Noticias: Buenas, aquí admin. Desde la Junta del Club Espace os pedimos a todos los usuarios registrados en nuestro foro que accedais a vuestra zona personal y elimineis aquellos mensajes personales que ya no son de utilidad. Estamos tratando de limpiar y mejorar el foro. Gracias por vuestra colaboración. |
| Â | Â | Inicio | Â | Ayuda | Buscar | Ingresar | Registrarse | Â |
The screen buzzed. The numbers recalculated.
Allows for energy savings when the building is empty.
You can typically download the official Trane BAYSENS019C Installation and Operation Manual directly from the Trane Literature database.
You can typically find the or the "Installation Operation and Maintenance" (IOM) guide through the following channels: trane baysens019c manual
Whether you are a building manager looking to optimize your property's climate control or an HVAC technician servicing a commercial unit, understanding how to install, program, and troubleshoot the BAYSENS019C is essential. This comprehensive guide serves as your complete manual for the Trane BAYSENS019C sensor. Technical Specifications and Compatibility
The BAYSENS019C relies on low-voltage connections to communicate with the main HVAC controller board. Terminal Label Function Description R 24 VAC Power Supply (Hot) C 24 VAC Common Y1 / Y2 Cooling Stages (First / Second Stage) W1 / W2 Heating Stages (First / Second Stage) G Indoor Fan / Blower Relay O / B Reversing Valve (For Heat Pump configurations) T1 / T2 Remote Temperature Sensor Connections (Optional)
Select the day or group of days you want to program using the arrows. Press to select the first period ( Wake ). The screen buzzed
If the power has been interrupted for an extended period, you may need to reset only the clock and day—the program remains stored in permanent memory.
Disconnect Terminals 3 and 4 and test the resistance of the sensor using a multimeter. Compare the resistance value against standard Trane thermistor charts (typically 10k ohms at 77°F / 25°C). 4. Schedule Loses Time Regularly Cause: Weak internal backup battery or capacitor failure.
Trane BAYSENS019C is a widely used programmable zone sensor primarily designed for commercial HVAC systems like Constant Volume (CV) and Heat Pump (HP) units. It is highly regarded for its durability You can typically download the official Trane BAYSENS019C
For complete, detailed instructions, always refer to the specific Trane ACC-SVN28A-EN manual that shipped with your unit, as settings can vary by application.
Connect wires to J6-11 and J6-12 on the ReliaTel board.
Connect four status signals (HEAT, COOL, ON, SERVICE) from the Unit Control Module to terminals 7, 8, 9, and 10.