To modify settings, you must enter Programming Mode. While in this mode, the indicator light changes color (typically flashing orange or red).

Power must cut off to unlock. Connect the lock to NC and COM .

Move the internal jumper (often labeled or S16 ) to pins 1-2 . Power the device on and wait for the beeps. Power off again and move the jumper back to pins 2-3 .

Swipe the RFID card or fob close to the keypad reader. (The machine will beep once). Press # to confirm, then press * to exit. Adding Users (PIN Only) Enter programming mode. Press 1 . Enter a unique (e.g., 0005 ) followed by # . Enter a 4-digit to 6-digit PIN . Press # . Press * to exit. V2000-c Rfid Access Control User Manual

To enter programming mode, you must use the . The factory default Master Code is 999999 .

The following technical specifications were compiled from multiple product listings and manuals. Please verify your device's exact specifications.

What (e.g., Maglock, electric strike) are you connecting? Are you integrating an external exit button or door sensor? Do you need assistance mapping out specific user slot IDs ? Share public link To modify settings, you must enter Programming Mode

and multiple entry modes including RFID cards (125KHz), PIN codes, or a combination of both. Sesame Access Co., Ltd. Technical Specifications Specification Power Supply 12VDC ± 10% User Capacity 1000 users Reading Distance 3 – 8 cm (1.18~2.36in) 125KHz EM Standard Unlock Relay Door Open Time Adjustable from 0 to 99 seconds Dimensions 119 x 76 x 21 mm (some models 118 x 118 x 20 mm) Installation and Wiring The unit should be mounted approximately 1.2 meters above the ground and roughly 0.5 meters from the door for optimal accessibility. +12V DC power. Black Wire: GND (Ground). Purple Wires: Doorbell button output. Wiegand Interface:

999999 (or sometimes 888888 depending on production batch).

| LEDs | Status | Meaning | |:-----|:-------|:--------| | Red only | Steady | System powered, idle mode | | Green + Red | Flashing | Card reading in progress | | Orange + Red | Steady | In programming mode | | Red + Green + Orange | Flashing | Initialization mode | | Green | Flash once | Access granted | Connect the lock to NC and COM

The V2000-c supports three operational modes. Switch using [Master Code] + # + 19 [Mode] # .

Ensure the backplate is firmly secured against the wall to depress the tamper switch. Check input voltage with a multimeter to ensure it reads a stable 12V DC. Keypad Fails to Accept Master Code Cause: The default master code was changed and forgotten. Hard Reset Procedure: Disconnect the power source. Press and hold the # key while restoring the power. Release the # key after hearing two short beeps.